Page 1 - VEGAPULS SR 68

Operating InstructionsRadar sensor for continuous level measurement of bulk solidsVEGAPULS SR 684 … 20 mA/HART - four-wireDocument ID: 38295

Page 2 - Quick start

103 Product descriptionVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-1306243 Product description3.1 CongurationThe nameplate contains the mos

Page 3

113 Product descriptionVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624This operating instructions manual applies to the following instrumen

Page 4 - Contents

123 Product descriptionVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624Unless otherwise indicated, the packages must be stored only under th

Page 5

133 Product descriptionVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624You will nd additional information in the supplementary instructions

Page 6 - 1 About this document

144 MountingVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-1306244 Mounting4.1 General instructionsOn instruments with process tting thread, th

Page 7 - 2 For your safety

154 MountingVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-1306243. Insert the antenna from below into the vessel socket and secure it against f

Page 8 - 2.7 Radio license for Europe

164 MountingVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624Note:A damaged O-ring seal must be replaced: FKM (SHS FPM 70C3 GLT), FFKM (Kalre

Page 9 - 2 For your safety

174 MountingVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-13062412Fig. 7: Position of the polarisation1 Marking with screwed version2 Marking

Page 10 - 3 Product description

184 MountingVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624Fig.9:MountingoftheradarsensorwithinowingmediumWith bulk solids silos

Page 11 - 3.2 Principle of operation

194 MountingVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624Fig.10:MountingoftheradarsensorwithinowingmediumThe socket piece shoul

Page 12 - 3 Product description

2Quick startVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624Quick startThe quick start procedure enables a quick setup with many applica-tio

Page 13

204 MountingVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624ca. 10 mmFig. 11: Recommended socket mounting with horn antenna> 10 mm (0.3

Page 14 - 4 Mounting

214 MountingVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624Fig. 13: Distance between antenna and socket with horn antennaFig. 14: Distance

Page 15

224 MountingVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624Socket diameter d Socket length h Recommended anten-na diameter40 mm 100 mm 40 m

Page 16 - 4.4 Mounting instructions

234 MountingVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624rrr.../13/12Fig. 16: OrientationIf mounting in the centre of the silo is not pos

Page 17

244 MountingVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624daαFig.17:ProposalforinstallationafterorientationVEGAPULSSR68The angle

Page 18

254 MountingVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624Proceed as follows to adjust the angle of inclination with the swivelling holder

Page 19

264 MountingVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624Fig. 19: AgitatorsLarge material heaps are detected with several sensors, which

Page 20 - > 10 mm

274 MountingVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624max. 50 mm (1.97")123Fig. 21: Mounting of the instrument on insulat

Page 21

284 MountingVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624sor should be mounted at a large distance from the separating wall. The optimal

Page 22

294 MountingVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624In case of extreme dust deposits in the antenna system, VEGAPULS SR 68 is availa

Page 23

3Quick startVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-1306243. Select in the menu item "Application" the vessel, the application

Page 24

305 Connecting to power supplyVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-1306245 Connecting to power supply5.1 Preparing the connectionAlwa

Page 25

315 Connecting to power supplyVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624Considerable potential dierences exist inside galvanic plants

Page 26

325 Connecting to power supplyVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624Fig. 27: Connection steps 5 and 65. Insert the wire ends into

Page 27

335 Connecting to power supplyVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-13062456784...20mA212+( )(-)1Fig.28:Electronicscompartment,doub

Page 28

345 Connecting to power supplyVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624power supply 4...20mA activepassivecommonIS GND51/L/N2+( )(-)

Page 29

356 Set up with the display and adjustment moduleVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-1306246 Set up with the display and adjustment m

Page 30 - 5 Connecting to power supply

366 Set up with the display and adjustment moduleVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-1306246.2 Adjustment system12Fig. 32: Display an

Page 31 - 5.2 Connection

376 Set up with the display and adjustment moduleVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624The main menu is divided into ve sections

Page 32 - 5 Connecting to power supply

386 Set up with the display and adjustment moduleVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624Enter the requested parameters via the appr

Page 33

396 Set up with the display and adjustment moduleVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624Storage tank on ships (Cargo Tank):• Produc

Page 34

4ContentsVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624Contents1 About this document1.1 Function ...

Page 35

406 Set up with the display and adjustment moduleVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624 – Buildup – Separation of oil and water po

Page 36 - 6.3 Parameter adjustment

416 Set up with the display and adjustment moduleVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624• Typical applications: – Instrument demons

Page 37

426 Set up with the display and adjustment moduleVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624 – Measurement near the lling streamCrushe

Page 38

436 Set up with the display and adjustment moduleVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624Enter the requested parameters via the appr

Page 39

446 Set up with the display and adjustment moduleVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-1306242. Edit the percentage value with [OK] and

Page 40

456 Set up with the display and adjustment moduleVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624When non-contact level sensors are used, th

Page 41

466 Set up with the display and adjustment moduleVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624changes over the operating time. In additio

Page 42

476 Set up with the display and adjustment moduleVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624Note:Check the distance to the product surf

Page 43

486 Set up with the display and adjustment moduleVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624user especially when adjusting the switchin

Page 44

496 Set up with the display and adjustment moduleVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624Menu Menu item Default valueSetup Measureme

Page 45

5ContentsVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-1306249.4 Rectify faults ...

Page 46

506 Set up with the display and adjustment moduleVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624manual "Display and adjustment module&

Page 47

517 Setup with PACTwareVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-1306247 Setup with PACTware7.1 Connect the PC312Fig. 34: Connection of th

Page 48

527 Setup with PACTwareVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624such cases, the interface converter can be connected parallel to the

Page 49

537 Setup with PACTwareVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624and echo curves. In addition, there is a tank calculation program as

Page 50

548 Set up with other systemsVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-1306248 Set up with other systems8.1 DD adjustment programsDevice d

Page 51 - 7 Setup with PACTware

559 Diagnosis, Asset Management and serviceVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-1306249 Diagnosis, Asset Management and service9.1 Mai

Page 52 - 7.2 Parameter adjustment

569 Diagnosis, Asset Management and serviceVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624• PC with PACTware/DTM • Control system with EDD

Page 53 - 7 Setup with PACTware

579 Diagnosis, Asset Management and serviceVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624Maintenance: Due to external inuences, the instr

Page 54 - 8 Set up with other systems

589 Diagnosis, Asset Management and serviceVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624CodeText mes-sageCause RecticationF260Error in t

Page 55 - 9.1 Maintenance

599 Diagnosis, Asset Management and serviceVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624CodeText mes-sageCause RecticationM500Error with

Page 56 - 4 Maintenance - blue

61 About this documentVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-1306241 About this document1.1 FunctionThis operating instructions manual p

Page 57

609 Diagnosis, Asset Management and serviceVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624Error Cause Rectication4 … 20 mA signal not stab

Page 58

619 Diagnosis, Asset Management and serviceVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624Measurement error with constant levelFault descri

Page 59 - 9.4 Rectify faults

629 Diagnosis, Asset Management and serviceVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624Measurement error during emptyingFault descriptio

Page 60

639 Diagnosis, Asset Management and serviceVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624• In the factory• Or on site by the userIn both c

Page 61 - 38295-EN-130624

6410 DismountingVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-13062410 Dismounting10.1 Dismounting stepsWarning:Before dismounting, be aware of

Page 62

6511 SupplementVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-13062411 Supplement11.1 Technical dataGeneral data316L corresponds to 1.4404 or 1.

Page 63 - 9.6 Software update

6611 SupplementVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-1306243421Fig. 47: Data of the input variable1 Reference plane2 Measured variable

Page 64 - 10 Dismounting

6711 SupplementVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624HART output values Ʋ PV (Primary Value) Distance to the level Ʋ SV (Secondary

Page 65 - 11 Supplement

6811 SupplementVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624Temperature drift - Current output ±0.03 %/10 K relating to the 16 mA span ma

Page 66

6911 SupplementVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624Seal Antenna impedance coneProcess temperature (measured on the process ttin

Page 67

72 For your safetyVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-1306242 For your safety2.1 Authorised personnelAll operations described in thi

Page 68

7011 SupplementVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624 Ʋ Cable gland M20 x 1.5 (cable: ø 5 … 9 mm) Ʋ Cable entry ½ NPT Ʋ Blind plug

Page 69

7111 SupplementVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624Integrated clockDate format Day.Month.YearTime format12 h/24 hTime zone Ex fa

Page 70

7211 SupplementVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624Housing1~ 87 mm (3.43")M16x1,5ø 84 mm(3.31")120 mm (4.72")M20x

Page 71 - 11.2 Dimensions

7311 SupplementVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624VEGAPULSSR68,hornantennainangeversionxy2160 mm(2.36")mminch8.50&

Page 72

7411 SupplementVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624VEGAPULS SR 68, horn antenna and swivelling holdermm inch 20 mm(0.79")20

Page 73

7511 SupplementVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624VEGAPULS SR 68, parabolic antenna and swivelling holder130 mm (5.12")ø 2

Page 74 - (0.59")

7611 SupplementVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-13062411.3 Industrial property rightsVEGA product lines are global protected by in

Page 75

77INDEXVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624INDEXAAccessories – Display and adjustment module 12 – External display and adjustme

Page 76 - 11.4 Trademark

78INDEXVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624TType plate 10VVessel form 42Vessel height 42Vessel installations 25Vessel insula

Page 77

79NotesVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-130624

Page 78

82 For your safetyVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-1306242.5 CE conformityThe device fullls the legal requirements of the applica

Page 79

Printing date:VEGA Grieshaber KGAm Hohenstein 11377761 SchiltachGermany38295-EN-130624All statements concerning scope of delivery, application, practi

Page 80 - Printing date:

92 For your safetyVEGAPULS SR 68 • 4 … 20 mA/HART - four-wire38295-EN-1306242.9 Environmental instructionsProtection of the environment is one of our