Summary of Contents

Page 1 - VEGABAR 55

Operating InstructionsPressure transmitter with METEC® measuring cellVEGABAR 554 … 20 mADocument ID: 36733

Page 2 - Contents

103 Product descriptionVEGABAR 55 • 4 … 20 mA36733-EN-130321• Storageandtransporttemperatureseechapter"Supplement - Technical data - Ambien

Page 3

114 MountingVEGABAR 55 • 4 … 20 mA36733-EN-1303214 Mounting4.1 General instructionsMake sure that all parts of the instrument coming in direct contac

Page 4 - 1 About this document

124 MountingVEGABAR 55 • 4 … 20 mA36733-EN-13032121212112Fig. 4: Position of the lter element1 Filter element2 Blind plugCaution:Duetotheltere

Page 5 - 2 For your safety

134 MountingVEGABAR 55 • 4 … 20 mA36733-EN-1303214.2 Mounting stepsFormountingVEGABAR55,aweldedsocketisrequired.Youcanndthesecomponents

Page 6 - 2 For your safety

144 MountingVEGABAR 55 • 4 … 20 mA36733-EN-13032190 mm (3.54")R 3,5 mm(0.14")3mm(0.12")70 mm (2.76")8 mm(0.32")93 mm (3.66&qu

Page 7 - 3 Product description

155 Connecting to power supplyVEGABAR 55 • 4 … 20 mA36733-EN-1303215 Connecting to power supply5.1 Preparing the connectionAlways keep in mind the f

Page 8 - 3.2 Principle of operation

165 Connecting to power supplyVEGABAR 55 • 4 … 20 mA36733-EN-130321housing.Thiswouldinuencethestabilityoftheconnectionandthetightness of t

Page 9 - 3.3 Operation

175 Connecting to power supplyVEGABAR 55 • 4 … 20 mA36733-EN-1303218. Press down the opening levers of the terminals, you will hear the terminal spri

Page 10 - 3 Product description

185 Connecting to power supplyVEGABAR 55 • 4 … 20 mA36733-EN-13032121Display4...20mA12Fig. 8: Electronics and connection compartment, single chamber h

Page 11 - 4 Mounting

195 Connecting to power supplyVEGABAR 55 • 4 … 20 mA36733-EN-1303215.5 Wiring plan, external housing with version IP 68Fig. 11: VEGABAR 55 in IP 68 v

Page 12

2ContentsVEGABAR 55 • 4 … 20 mA36733-EN-130321Contents1 About this document1.1 Function ...

Page 13 - 4.2 Mounting steps

205 Connecting to power supplyVEGABAR 55 • 4 … 20 mA36733-EN-1303211234634125Fig. 13: Connection of the sensor in the housing socket1 Brown2 Blue3

Page 14

215 Connecting to power supplyVEGABAR 55 • 4 … 20 mA36733-EN-130321Then the corresponding current is outputted to the cable (the value corresponds to

Page 15 - 5 Connecting to power supply

226 Set up with the display and adjustment module PLICSCOMVEGABAR 55 • 4 … 20 mA36733-EN-1303216 Set up with the display and adjustment module PLICSC

Page 16 - 5.2 Connection procedure

236 Set up with the display and adjustment module PLICSCOMVEGABAR 55 • 4 … 20 mA36733-EN-130321Fig. 15: Insert display and adjustment moduleNote:Ifyo

Page 17 - 5 Connecting to power supply

246 Set up with the display and adjustment module PLICSCOMVEGABAR 55 • 4 … 20 mA36733-EN-130321 – Save value• [->] key to select: – Menu change – S

Page 18

256 Set up with the display and adjustment module PLICSCOMVEGABAR 55 • 4 … 20 mA36733-EN-130321The actual measured value is also displayed in the menu

Page 19

266 Set up with the display and adjustment module PLICSCOMVEGABAR 55 • 4 … 20 mA36733-EN-130321Density0001000kg/dm³6. Enter the requested density val

Page 20

276 Set up with the display and adjustment module PLICSCOMVEGABAR 55 • 4 … 20 mA36733-EN-130321Iftheadjustmentrangesareexceeded,themessage&quo

Page 21

286 Set up with the display and adjustment module PLICSCOMVEGABAR 55 • 4 … 20 mA36733-EN-130321The display and adjustment module enables the adjustmen

Page 22 - 6.1 Short description

296 Set up with the display and adjustment module PLICSCOMVEGABAR 55 • 4 … 20 mA36733-EN-130321The adjustment unit is thus switched over from bar to m

Page 23 - 6.3 Adjustment system

3ContentsVEGABAR 55 • 4 … 20 mA36733-EN-1303218 Dismounting8.1 Dismounting steps...

Page 24 - 6.4 Setup steps

306 Set up with the display and adjustment module PLICSCOMVEGABAR 55 • 4 … 20 mA36733-EN-130321Proceed as follows:1. Editthembarvalueinthemenu

Page 25

316 Set up with the display and adjustment module PLICSCOMVEGABAR 55 • 4 … 20 mA36733-EN-130321The following data are read out or written with this fu

Page 26 - Selection options: °C, °F

326 Set up with the display and adjustment module PLICSCOMVEGABAR 55 • 4 … 20 mA36733-EN-130321Menu section Function ResetvalueDisplay Displayed valu

Page 27 - 0000.0 mbar

336 Set up with the display and adjustment module PLICSCOMVEGABAR 55 • 4 … 20 mA36733-EN-130321Basic adjustment▶Basic adjustment 1DisplayDiagnosticsSe

Page 28

346 Set up with the display and adjustment module PLICSCOMVEGABAR 55 • 4 … 20 mA36733-EN-130321ServiceBasic adjustment 4DisplayDiagnostics▶ServiceInfo

Page 29

356 Set up with the display and adjustment module PLICSCOMVEGABAR 55 • 4 … 20 mA36733-EN-130321

Page 30

367MaintenanceandfaultrecticationVEGABAR 55 • 4 … 20 mA36733-EN-1303217 Maintenanceandfaultrectication7.1 MaintainIf the instrument is used

Page 31

377MaintenanceandfaultrecticationVEGABAR 55 • 4 … 20 mA36733-EN-130321Error code Cause Rectication4 … 20 mA signal not stableLeveluctuations

Page 32 - 6.5 Menu schematic

387MaintenanceandfaultrecticationVEGABAR 55 • 4 … 20 mA36733-EN-130321Fperf=√((FT)2 + (FKl)2 + (Fa)2)With:• Ftotal: Total deviation• Fperf: Bas

Page 33

397MaintenanceandfaultrecticationVEGABAR 55 • 4 … 20 mA36733-EN-130321Total deviation analogue output signal absolute:Ftotal = 0.365 % x 8 bar/10

Page 34

41 About this documentVEGABAR 55 • 4 … 20 mA36733-EN-1303211 About this document1.1 FunctionThis operating instructions manual provides all the infor

Page 35 - 36733-EN-130321

407MaintenanceandfaultrecticationVEGABAR 55 • 4 … 20 mA36733-EN-130321data and displays the actual hardware and software version of the sensor. T

Page 36 - 7.2 Rectifyfaults

418 DismountingVEGABAR 55 • 4 … 20 mA36733-EN-1303218 Dismounting8.1 Dismounting stepsWarning:Before dismounting, be aware of dangerous process condi

Page 37 - DIN16086)

429 SupplementVEGABAR 55 • 4 … 20 mA36733-EN-1303219 Supplement9.1 Technical dataGeneral dataPressure type Gauge pressure, absolute pressure, vacuumM

Page 38

439 SupplementVEGABAR 55 • 4 … 20 mA36733-EN-130321 Ʋ Connection cable with IP 68 1 bar versionPE,PURWeight approx. 0.8 … 8 kg (1.764 … 17.64 lbs), d

Page 39 - 7.5 Software update

449 SupplementVEGABAR 55 • 4 … 20 mA36733-EN-130321 Ʋ Span -120 … +120 % 7) Ʋ Dierencebetweenzeroandspan max. 120 % of the nominal rangeRecommend

Page 40 - 7.6 Instrument repair

459 SupplementVEGABAR 55 • 4 … 20 mA36733-EN-130321Nominalrange Overload capacity, max. pressureOverload capacity, min. pres-sure0 … +1.5 psig +200 p

Page 41 - 8 Dismounting

469 SupplementVEGABAR 55 • 4 … 20 mA36733-EN-130321Deviation with version 0.075 % Ʋ Turn down 1 : 1 up to 5 : 1 < 0.075 % Ʋ Turn down > 5 : 1 &l

Page 42 - 9 Supplement

479 SupplementVEGABAR 55 • 4 … 20 mA36733-EN-130321 Ʋ For one year < 0.05 % x TD Ʋ Forveyears < 0.1 % x TD Ʋ For ten years < 0.2 % x TDAmb

Page 43

489 SupplementVEGABAR 55 • 4 … 20 mA36733-EN-130321Spring-loaded terminals for wire cross-section< 2.5 mm² (AWG 14)Electromechanical data - version

Page 44

499 SupplementVEGABAR 55 • 4 … 20 mA36733-EN-130321Display and adjustment moduleVoltage supply and data transmission through the sensorIndication LC d

Page 45

52 For your safetyVEGABAR 55 • 4 … 20 mA36733-EN-1303212 For your safety2.1 Authorised personnelAll operations described in this operating instructi

Page 46 - 40°C 60°C 80°C

509 SupplementVEGABAR 55 • 4 … 20 mA36733-EN-130321 Ʋ Housing, standard IP 66/IP 6713) Ʋ Aluminium and stainless housing (optionally available)IP 68 (

Page 47

519 SupplementVEGABAR 55 • 4 … 20 mA36733-EN-1303219.2 DimensionsPlastic housing~ 69 mm(2.72")ø 79 mm(3.03")112 mm (4.41")M20x1,5/½ NPT

Page 48

529 SupplementVEGABAR 55 • 4 … 20 mA36733-EN-130321Aluminium housing in protection rating IP 66/IP 68 (1 bar)120 mm (4.72")~ 105 mm (4.13")1

Page 49 - 3 Operating voltage

539 SupplementVEGABAR 55 • 4 … 20 mA36733-EN-130321Stainless steel housing in protection rating IP 66/IP 68 (1 bar)117 mm (4.61")~ 103 mm(4.06&qu

Page 50

549 SupplementVEGABAR 55 • 4 … 20 mA36733-EN-13032112368 mm(2.68")68 mm(2.68")92 mm(3.62")42mm(1.65")40mm(1.57")110 mm x 90 m

Page 51 - Aluminium housing

559 SupplementVEGABAR 55 • 4 … 20 mA36733-EN-130321VEGABAR55,threadedttingGG GL - 180°CGNGG - 180°C/200°CBA / BB BE78 mm(3 5/64")118 mm(4 41/

Page 52 - Stainless steel housing

569 SupplementVEGABAR 55 • 4 … 20 mA36733-EN-130321VEGABAR55,hygienictting178 mm(3 5/64")78 mm(3 5/64")ø 64 mm(2 33/64")78 mm(3 5/

Page 53

579 SupplementVEGABAR 55 • 4 … 20 mA36733-EN-130321VEGABAR55,hygienictting278 mm(3 5/64")78 mm(3 5/64")78 mm(3 5/64")78 mm(3 5/64&

Page 54

589 SupplementVEGABAR 55 • 4 … 20 mA36733-EN-130321VEGABAR55,angeconnection3 15/32"4 1/64"5 7/16" 1/8" 1/8" 1/8"4xø

Page 55 - BA / BB BE

599 SupplementVEGABAR 55 • 4 … 20 mA36733-EN-1303219.3 Industrial property rightsVEGA product lines are global protected by industrial property right

Page 56 - CA/CF CB

62 For your safetyVEGABAR 55 • 4 … 20 mA36733-EN-1303212.6 CE conformityThisdevicefulllsthelegalrequirementsoftheapplicableECguide-lines.

Page 57 - VEGABAR55,hygienictting2

60INDEXVEGABAR 55 • 4 … 20 mA36733-EN-130321INDEXAAccessories – Display and adjustment module 10 – Flanges 10 – Measuring instrument holder 10 – Pr

Page 58 - VEGABAR55,angeconnection

61NotesVEGABAR 55 • 4 … 20 mA36733-EN-130321

Page 59 - 9.4 Trademark

62NotesVEGABAR 55 • 4 … 20 mA36733-EN-130321

Page 60

63NotesVEGABAR 55 • 4 … 20 mA36733-EN-130321

Page 61

Printing date:VEGA Grieshaber KGAm Hohenstein 11377761 SchiltachGermany36733-EN-130321All statements concerning scope of delivery, application, practi

Page 62

73 Product descriptionVEGABAR 55 • 4 … 20 mA36733-EN-1303213 Product description3.1 CongurationThe scope of delivery encompasses:• VEGABAR 55 press

Page 63

83 Product descriptionVEGABAR 55 • 4 … 20 mA36733-EN-1303212113105436789111214Fig. 2: Layout of the type label (example)1 Instrument type2 Product c

Page 64 - Printing date:

93 Product descriptionVEGABAR 55 • 4 … 20 mA36733-EN-1303214 … 20 mA two-wire electronics for voltage supply and measured value transmission on the sa