Vega VEGAPULS 62 (≥ 2.0.0 - ≥ 4.0.0) Profibus PA User Manual

Browse online or download User Manual for Equipment Vega VEGAPULS 62 (≥ 2.0.0 - ≥ 4.0.0) Profibus PA. VEGA VEGAPULS 62 (≥ 2.0.0 - ≥ 4.0.0) Profibus PA User Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - VEGAPULS 62

Operating InstructionsRadar sensor for continuous level measurement of liquidsVEGAPULS 62Probus PADocument ID: 36505

Page 2 - Quick start

103 Product descriptionVEGAPULS 62 • Probus PA36505-EN-1210113 Product description3.1 CongurationThe type label contains the most important data f

Page 3

113 Product descriptionVEGAPULS 62 • Probus PA36505-EN-121011The instrument is available in two dierent electronics versions. Each version can be id

Page 4 - Contents

123 Product descriptionVEGAPULS 62 • Probus PA36505-EN-1210113.3 Packaging, transport and storageYour instrument was protected by packaging during t

Page 5

133 Product descriptionVEGAPULS 62 • Probus PA36505-EN-121011It is suitable for measured value indication and adjustment of plics® sensors and is con

Page 6 - 1 About this document

144 MountingVEGAPULS 62 • Probus PA36505-EN-1210114 Mounting4.1 General instructionsWith instruments with threaded process tting, suitable tools mu

Page 7 - 2 For your safety

154 MountingVEGAPULS 62 • Probus PA36505-EN-1210113 4 1 2 Fig. 5: Dismounting of the horn antenna1 Marking of the polarisation plane2 Marking at th

Page 8

164 MountingVEGAPULS 62 • Probus PA36505-EN-121011cient air ow (the air is led through the holes to the feed system. A rinsing of the whole parabol

Page 9

174 MountingVEGAPULS 62 • Probus PA36505-EN-121011is expected. In this case, we recommend repeating a false echo stor-age later with existing buildup

Page 10 - 3 Product description

184 MountingVEGAPULS 62 • Probus PA36505-EN-121011Fig.10:MountingoftheradarsensorwithinowingmediumThe socket piece should be dimensioned in

Page 11

194 MountingVEGAPULS 62 • Probus PA36505-EN-121011sensor increases. Additional false reections may be generated which can inuence the measuring res

Page 12

2Quick startVEGAPULS 62 • Probus PA36505-EN-121011Quick startThe quick start enables a quick setup with many applications. You can nd further inform

Page 13

204 MountingVEGAPULS 62 • Probus PA36505-EN-121011Socket diameter d Socket length h Recommended anten-na diameter40 mm 100 mm 40 mm50 mm 150 mm 48 mm

Page 14 - 4 Mounting

214 MountingVEGAPULS 62 • Probus PA36505-EN-121011Small, inclined sheet metal baes above the installations scatter the radar signals and prevent dir

Page 15 - 4 Antenna

224 MountingVEGAPULS 62 • Probus PA36505-EN-1210110%100%123123458679Fig.19:Congurationsurgepipe1 Radar sensor2 Marking of the polarisation pla

Page 16

234 MountingVEGAPULS 62 • Probus PA36505-EN-121011Constructional requirements on the surge pipe:• Material metal, smoother inner tube• Preferably pul

Page 17 - > 200 mm

244 MountingVEGAPULS 62 • Probus PA36505-EN-121011Instructions for orientation:• Note marking of the polarisation plane on the sensor• With threaded

Page 18 - (0.39")

254 MountingVEGAPULS 62 • Probus PA36505-EN-121011max. 50 mm (1.97")123Fig. 21: Mounting of the instrument with insulated vessels.1 Ele

Page 19

264 MountingVEGAPULS 62 • Probus PA36505-EN-12101123 ... 4 x hmax90°hmaxdB1Fig.23:FlowmeasurementwithKhafagi-Venturiume:d=Min.distanceto

Page 20

275 Connecting to the bus systemVEGAPULS 62 • Probus PA36505-EN-1210115 Connecting to the bus system5.1 Preparing the connectionAlways keep in mind

Page 21 - Fig. 18: Agitators

285 Connecting to the bus systemVEGAPULS 62 • Probus PA36505-EN-121011ceramic capacitor (e.g. 1 nF, 1500 V). Low-frequency potential equali-sation cu

Page 22

295 Connecting to the bus systemVEGAPULS 62 • Probus PA36505-EN-121011You can nd further information to the max. wire cross-section under "Tech

Page 23

3Quick startVEGAPULS 62 • Probus PA36505-EN-1210113. Select in the menu item "Application" the vessel, the application and the vessel form

Page 24

305 Connecting to the bus systemVEGAPULS 62 • Probus PA36505-EN-121011115005162738490516273849101678Bus2312+( )(-)Fig. 26: Electronics compartment,

Page 25

315 Connecting to the bus systemVEGAPULS 62 • Probus PA36505-EN-1210115.5 Wiring plan, double chamber housing Ex d415005162738490516273849101678Bus2

Page 26 - 2 Venturiume

325 Connecting to the bus systemVEGAPULS 62 • Probus PA36505-EN-121011Contact pin Colour connection ca-ble in the sensorTerminal, electronics moduleP

Page 27 - 5.1 Preparing the connection

335 Connecting to the bus systemVEGAPULS 62 • Probus PA36505-EN-1210115005162738490516273849101678Bus21312+( )(-)Fig. 33: Address selection switch1

Page 28 - 5.2 Connecting

346 Set up with the indicating and adjustment moduleVEGAPULS 62 • Probus PA36505-EN-1210116 Set up with the indicating and adjustment module6.1 Ins

Page 29

356 Set up with the indicating and adjustment moduleVEGAPULS 62 • Probus PA36505-EN-1210111 2Fig. 35: Insertion of the indicating and adjustment modu

Page 30 - SIM-Card

366 Set up with the indicating and adjustment moduleVEGAPULS 62 • Probus PA36505-EN-121011 – Edit parameter – Save value• [->] key: – Presentation

Page 31

376 Set up with the indicating and adjustment moduleVEGAPULS 62 • Probus PA36505-EN-121011tion. With bulk solids, these are dust generation, material

Page 32

386 Set up with the indicating and adjustment moduleVEGAPULS 62 • Probus PA36505-EN-121011• Process/measurement conditions: – Condensation – Smooth p

Page 33

396 Set up with the indicating and adjustment moduleVEGAPULS 62 • Probus PA36505-EN-121011 – Joins like anges, weld joints – Shifting of the running

Page 34

4ContentsVEGAPULS 62 • Probus PA36505-EN-121011Contents1 About this document1.1 Function ...

Page 35 - 6.2 Adjustment system

406 Set up with the indicating and adjustment moduleVEGAPULS 62 • Probus PA36505-EN-121011 – Exact measurement result required – Distance to the wate

Page 36 - 6.3 Parameter adjustment

416 Set up with the indicating and adjustment moduleVEGAPULS 62 • Probus PA36505-EN-121011• Vessel of concrete or metal, also multiple chamber silo:

Page 37

426 Set up with the indicating and adjustment moduleVEGAPULS 62 • Probus PA36505-EN-121011Enter the requested parameters via the appropriate keys, sa

Page 38

436 Set up with the indicating and adjustment moduleVEGAPULS 62 • Probus PA36505-EN-121011specications is always the seal surface of the thread or 

Page 39

446 Set up with the indicating and adjustment moduleVEGAPULS 62 • Probus PA36505-EN-1210114. Enter the appropriate distance value in m (correspondin

Page 40

456 Set up with the indicating and adjustment moduleVEGAPULS 62 • Probus PA36505-EN-121011A comparison of echo curve and false signal suppression all

Page 41

466 Set up with the indicating and adjustment moduleVEGAPULS 62 • Probus PA36505-EN-1210112. Conrm again with [OK].3. Conrm again with [OK].4. C

Page 42

476 Set up with the indicating and adjustment moduleVEGAPULS 62 • Probus PA36505-EN-121011By activating the appropriate curve, the volume percentage

Page 43

486 Set up with the indicating and adjustment moduleVEGAPULS 62 • Probus PA36505-EN-121011• Peak values measured value: Resetting of the measured min

Page 44

496 Set up with the indicating and adjustment moduleVEGAPULS 62 • Probus PA36505-EN-121011adjustment module. The procedure is described in the operat

Page 45

5ContentsVEGAPULS 62 • Probus PA36505-EN-1210119.1 Maintenance ... 539.2 Measured

Page 46

507 Setup with PACTwareVEGAPULS 62 • Probus PA36505-EN-1210117 Setup with PACTware7.1 Connect the PC312Fig. 38: Connection of the PC directly to th

Page 47

517 Setup with PACTwareVEGAPULS 62 • Probus PA36505-EN-121011Fig. 39: Example of a DTM viewAll device DTMs are available as a free-of-charge standard

Page 48

528 Set up with other systemsVEGAPULS 62 • Probus PA36505-EN-1210118 Set up with other systems8.1 DD adjustment programsDevice descriptions as Enha

Page 49

539 Diagnosis, Asset Management and serviceVEGAPULS 62 • Probus PA36505-EN-1210119 Diagnosis, Asset Management and service9.1 MaintenanceIf the devi

Page 50 - 7 Setup with PACTware

549 Diagnosis, Asset Management and serviceVEGAPULS 62 • Probus PA36505-EN-121011Further echo curves: Up to 10 echo curves can be stored in a ring bu

Page 51

559 Diagnosis, Asset Management and serviceVEGAPULS 62 • Probus PA36505-EN-121011The following table shows the codes and text messages of the status

Page 52 - 8 Set up with other systems

569 Diagnosis, Asset Management and serviceVEGAPULS 62 • Probus PA36505-EN-121011CodeText mes-sageCause Rectication PA DevS-pecDiagnosisF260Error in

Page 53

579 Diagnosis, Asset Management and serviceVEGAPULS 62 • Probus PA36505-EN-121011The following table shows the error codes and text messages in the s

Page 54 - 4 Maintenance - blue

589 Diagnosis, Asset Management and serviceVEGAPULS 62 • Probus PA36505-EN-121011The below tables show typical examples of application-related meas-u

Page 55

599 Diagnosis, Asset Management and serviceVEGAPULS 62 • Probus PA36505-EN-1210119.4 MeasurementerrorduringllingFault description Error pattern

Page 56

61 About this documentVEGAPULS 62 • Probus PA36505-EN-1210111 About this document1.1 FunctionThis operating instructions manual provides all the inf

Page 57 - 9.4 Rectify faults

609 Diagnosis, Asset Management and serviceVEGAPULS 62 • Probus PA36505-EN-1210119.4 Measurement error during emptyingFault description Error patter

Page 58

619 Diagnosis, Asset Management and serviceVEGAPULS 62 • Probus PA36505-EN-121011In both cases, the serial number of the sensor is needed. The serial

Page 59

6210 DismountingVEGAPULS 62 • Probus PA36505-EN-12101110 Dismounting10.1 Dismounting stepsWarning:Before dismounting, be aware of dangerous process

Page 60

6311 SupplementVEGAPULS 62 • Probus PA36505-EN-12101111 Supplement11.1 Technical dataGeneral data316L corresponds to 1.4404 or 1.4435Materials, wett

Page 61

6411 SupplementVEGAPULS 62 • Probus PA36505-EN-121011Input variableMeasured variable The measured quantity is the distance between process tting of

Page 62 - 10 Dismounting

6511 SupplementVEGAPULS 62 • Probus PA36505-EN-121011Number of FBs with AI (function blocks with analogue input)3Default values Ʋ 1. FB PV Ʋ 2. FB SV

Page 63 - 11 Supplement

6611 SupplementVEGAPULS 62 • Probus PA36505-EN-121011Additional deviation through strong, high frequency electromagnetic elds acc. to EN 61326< ±

Page 64 - 4 Useful measuring range

6711 SupplementVEGAPULS 62 • Probus PA36505-EN-121011Emitted HF power (depending on the parameter adjustment)3) Ʋ Average spectral transmission power

Page 65 - 2 Antenna edge

6811 SupplementVEGAPULS 62 • Probus PA36505-EN-121011 Ʋ Horn antenna 4 g at 5 … 200 Hz according to EN60068-2-6 (vibration with resonance) Ʋ Paraboli

Page 66

6911 SupplementVEGAPULS 62 • Probus PA36505-EN-121011Electromechanical data - version IP 66/IP 68 (1 bar)Options of the cable entry Ʋ Cable gland wit

Page 67

72 For your safetyVEGAPULS 62 • Probus PA36505-EN-1210112 For your safety2.1 Authorised personnelAll operations described in this operating instruc

Page 68

7011 SupplementVEGAPULS 62 • Probus PA36505-EN-121011 Ʋ EEx-ia instrument - Power supply FISCO model9 … 17.5 V DC Ʋ EEx-ia instrument - Power supply

Page 69

7111 SupplementVEGAPULS 62 • Probus PA36505-EN-121011Device name Instrument ID GSDlenameVEGA Instrument class in prole3.02VEGA Prole-specicVEG

Page 70 - 11.3 ID number

7211 SupplementVEGAPULS 62 • Probus PA36505-EN-12101111.5 Module of the PA sensorsFor the cyclic data trac, VEGAPULS 62 provides the following modu

Page 71 - 11.4 Cyclicaldatatrac

7311 SupplementVEGAPULS 62 • Probus PA36505-EN-12101111.7 Data format of the output signalByte4Byte3Byte2Byte1Byte0Status Value (IEEE-754)Fig. 58: D

Page 72

7411 SupplementVEGAPULS 62 • Probus PA36505-EN-121011Status code Description according to ProbusstandardPossible cause0 x 51 uncertain - sensor; co

Page 73

7511 SupplementVEGAPULS 62 • Probus PA36505-EN-121011Aluminium housing21ø 86 mm (3.39")~ 116 mm (4.57")116 mm (4.57")M20x1,5M20x1,5/½

Page 74 - Plastic housing

7611 SupplementVEGAPULS 62 • Probus PA36505-EN-121011Stainless steel housing~ 69 mm(2.72")ø 79 mm(3.11")117 mm (4.61")M20x1,5/½ NPT~ 5

Page 75 - Aluminium housing

7711 SupplementVEGAPULS 62 • Probus PA36505-EN-121011VEGAPULS 62, horn antenna in threaded versionmm inch 38 mm (1.50")22 mm (0.87")22 mm (

Page 76 - Stainless steel housing

7811 SupplementVEGAPULS 62 • Probus PA36505-EN-121011VEGAPULS62,hornantennainangeversionxy21165 mm (6.5")60 mm(2.36")mminch8.50"

Page 77 - 1 Standard

7911 SupplementVEGAPULS 62 • Probus PA36505-EN-121011VEGAPULS62,hornantennainangeversion450°Cyxinch8.50"11.30"ø 1.89"ø 2.95&q

Page 78

82 For your safetyVEGAPULS 62 • Probus PA36505-EN-1210112.5 CE conformityThe device fullls the legal requirements of the applicable EC guide-lines.

Page 79 - 36505-EN-121011

8011 SupplementVEGAPULS 62 • Probus PA36505-EN-121011VEGAPULS 62, horn antenna and swivelling holdermm inch 20 mm(0.79")20 mm(0.79")3.94&qu

Page 80

8111 SupplementVEGAPULS 62 • Probus PA36505-EN-121011VEGAPULS 62, parabolic antenna and swivelling holder130 mm (5.12")ø 243 mm (9.57")140

Page 81

8211 SupplementVEGAPULS 62 • Probus PA36505-EN-12101111.4 Industrial property rightsVEGA product lines are global protected by industrial property r

Page 82 - 11.5 Trademark

83INDEXVEGAPULS 62 • Probus PA36505-EN-121011INDEXAAccessories – External indicating and adjustment unit 12 – External radio unit 13 – Flanges 13

Page 83

84INDEXVEGAPULS 62 • Probus PA36505-EN-121011SSensor orientation 20Service hotline 60Socket 18Software addressing 33Status bytes PA output value

Page 84

85NotesVEGAPULS 62 • Probus PA36505-EN-121011

Page 85

86NotesVEGAPULS 62 • Probus PA36505-EN-121011

Page 86

87NotesVEGAPULS 62 • Probus PA36505-EN-121011

Page 87

Printing date:VEGA Grieshaber KGAm Hohenstein 11377761 SchiltachGermany36505-EN-121011All statements concerning scope of delivery, application, practi

Page 88 - Printing date:

92 For your safetyVEGAPULS 62 • Probus PA36505-EN-1210112.9 Environmental instructionsProtection of the environment is one of our most important dut

Comments to this Manuals

No comments