Supplementary instructions
PLICSMOBILE
GSM/GPRS radio module
Document ID:
36849
Signal
conditioning instruments
and communication
Page view 0
1 2 3 4 5 6 ... 22 23

Summary of Contents

Page 1

Supplementary instructionsPLICSMOBILEGSM/GPRS radio moduleDocument ID:36849Signalconditioning instrumentsand communication

Page 2

Number of mes-sages/dayAnnual consumption PLICSMOBILEStandby energydemandEnergy demandfor messagetransmissionRequired bat-tery capacitancewith 12 V4 2

Page 3

mode. In such case, the sensor consumes constantly only 4 mAindependent of the measured level, which can increase battery lifeconsiderably. A descript

Page 4

5 Set up5.1 Adjustment systemA pC with PACTware and respective DTM is required for setup.The connection is carried out via a standard mini USB cable (

Page 5

Note:The connection via USB requires a driver. First of all, install the driverbefore connecting PLICSMOBILE to the PC.The required USB driver is incl

Page 6

All device DTMs are available as a free-of-charge standardversion and as a full version that must be purchased. In the standardversion, all functions

Page 7

energy saving mode is activated, this block rounding is applied witheach transmission. If for example a tariff with a block rounding to100 KB is used,

Page 8

DTM menu "Network information" under "Setup - Diagnosis". You canalso see the general device status via the status indication.The

Page 9

Fig. 7: Input of the Internet access dataThe measured values can be transmitted optionally in thefollowing ways:l Via intergrated mail client to any e

Page 10

Fig. 8: Input of the e-mail access dataFor measured value transmission via SMS, no furterh access data arerequired because all specifications are alrea

Page 11

6 Maintenance and fault rectification6.1 MaintenanceIf the instrument is used properly, no special maintenance is requiredin normal operation.6.2 Remov

Page 12

Contents1 Product description1.1 Structure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31.2 Principle of operation . . . . . . .

Page 13

? E030l Sensor in boot phasel value not validà Check sensor parameter adjustment? E034l EEPROM CRC errorà Switch the instrument off and onà Carry out a

Page 14

Depending on the reason for the fault and the measures taken, thesteps described in chapter "Set up" may have to be carried out again.Reacti

Page 15

7 Supplement7.1 Technical dataVoltage supplyOperating voltage1)8 … 32 V DCPower consumption2)- Power saving mode (9 V/12 V) 0.18 mW/0.3 mW- Power savi

Page 16

ApprovalsInstruments with approvals can have different technical data depending on the version.That's why the associated approval documents have t

Page 18

1 Product description1.1 StructureNote:This supplementary instructions manual describes the optionallyavailable GSM/GPRS radio module PLICMOBILE which

Page 19

1.2 Principle of operationThe PLICSMOBILE is a GSM/GPRS radio unit fortransmission of measured values and for remote parameter adjust-ment of plics®se

Page 20

2 Mounting2.1 General instructionsInformation:You can find the general mounting instructions in the operatinginstructions manual of the respective sens

Page 21

3 Connecting to power supply3.1 Preparing the connectionNote:You can find the general connection instructions in the operatinginstructions manual of th

Page 22

Fig. 2: Connection steps 4 and 55 Insert the wire ends into the terminals according to the wiring planInformation:Solid cores as well as flexible cores

Page 23

3.4 Connection steps sensor electronicsThese steps must only be carried out if the sensor electronics is to bepowered via an additional voltage supply

Page 24

4 Battery operation and power saving mode4.1 Battery operationIf no network-supported voltage supply is available,PLICSMOBILE can be also powered via