Operating InstructionsPressure transmitter with MINI-CERTEC® measuring cellVEGABAR 544 … 20 mA/HARTDocument ID: 36726

Page 2 - Contents

103 Product descriptionVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321The delivery must be checked for completeness and possible transit damage immediately

Page 3

113 Product descriptionVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321Youcanndadditionalinformationinthesupplementaryinstructionsmanual"Fla

Page 4 - 1 About this document

124 MountingVEGABAR 54 • 4 … 20 mA/HART36726-EN-1303214 Mounting4.1 General instructionsMake sure that all parts of the instrument coming in direct c

Page 5 - 2 For your safety

134 MountingVEGABAR 54 • 4 … 20 mA/HART36726-EN-13032121212112Fig. 4: Position of the lter element1 Filter element2 Blind plugCaution:Duetothel

Page 6 - 2 For your safety

144 MountingVEGABAR 54 • 4 … 20 mA/HART36726-EN-1303214.2 Mounting stepsFormountingVEGABAR54,aweldedsocketisrequired.Youcanndthesecompo

Page 7 - 3 Product description

154 MountingVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321Tip:Mount the wall mounting plate so that the cable entry of the socket housing points downward.

Page 8 - 3.2 Principle of operation

165 Connecting to power supplyVEGABAR 54 • 4 … 20 mA/HART36726-EN-1303215 Connecting to power supply5.1 Preparing the connectionAlways keep in mind

Page 9 - 3.3 Operation

175 Connecting to power supplyVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321housing.Thiswouldinuencethestabilityoftheconnectionandthetightness

Page 10 - 3 Product description

185 Connecting to power supplyVEGABAR 54 • 4 … 20 mA/HART36726-EN-1303218. Press down the opening levers of the terminals, you will hear the terminal

Page 11

195 Connecting to power supplyVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321321Fig. 8: Components of the external housing1 Screws2 Wall mounting plate3

Page 12 - 4 Mounting

2ContentsVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321Contents1 About this document1.1 Function ...

Page 13

205 Connecting to power supplyVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321I²CDisplay12 56783412Fig. 9: Electronics and connection compartment, single ch

Page 14 - 4.2 Mounting steps

215 Connecting to power supplyVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321132Display12 5678I2CFig. 11: Electronics compartment, double chamber housing1

Page 15

225 Connecting to power supplyVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321I2C112Fig. 13: Wiring plan, double chamber housing1 Voltage supply, signal ou

Page 16 - 5 Connecting to power supply

235 Connecting to power supplyVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321567812DisplayI²C21543Fig. 16: Electronics and connection compartment1 Spring-

Page 17 - 5.2 Connection procedure

245 Connecting to power supplyVEGABAR 54 • 4 … 20 mA/HART36726-EN-1303211234634125Fig. 17: Connection of the sensor in the housing socket1 Brown2 Bl

Page 18 - 5 Connecting to power supply

255 Connecting to power supplyVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321Then the corresponding current is outputted to the cable (the value correspond

Page 19

266 Set up with the display and adjustment module PLICSCOMVEGABAR 54 • 4 … 20 mA/HART36726-EN-1303216 Set up with the display and adjustment module P

Page 20

276 Set up with the display and adjustment module PLICSCOMVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321Fig. 19: Insert display and adjustment moduleNote:

Page 21 - Connection compartment

286 Set up with the display and adjustment module PLICSCOMVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321 – Save value• [->] key to select: – Menu chang

Page 22

296 Set up with the display and adjustment module PLICSCOMVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321Information:The steps 1, 3 and 4 are not necessary

Page 23

3ContentsVEGABAR 54 • 4 … 20 mA/HART36726-EN-1303218 Maintenanceandfaultrectication8.1 Maintain ...

Page 24

306 Set up with the display and adjustment module PLICSCOMVEGABAR 54 • 4 … 20 mA/HART36726-EN-1303214. Conrmwith[OK],thesubmenu"Density un

Page 25

316 Set up with the display and adjustment module PLICSCOMVEGABAR 54 • 4 … 20 mA/HART36726-EN-1303214. Set the requested mbar value with [+] and [-&g

Page 26 - 6.1 Short description

326 Set up with the display and adjustment module PLICSCOMVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321Inthemenuitems"zero"and"span&

Page 27 - 6.3 Adjustment system

336 Set up with the display and adjustment module PLICSCOMVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321UnitUnitofmeasurementbar▼Temperature unit°C▼3.

Page 28 - 6.4 Setup steps

346 Set up with the display and adjustment module PLICSCOMVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321Information:Thezeroadjustmentshiftsthevalueo

Page 29

356 Set up with the display and adjustment module PLICSCOMVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321• SIL• HART mode6)• PIN• ApplicationCopy sensor da

Page 30 - Selection options: °C, °F

366 Set up with the display and adjustment module PLICSCOMVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321Menu section Function ResetvalueDamping 1 sLinear

Page 31 - 0000.0 mbar

376 Set up with the display and adjustment module PLICSCOMVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321Basic adjustment▶Basic adjustment 1DisplayDiagnost

Page 32

386 Set up with the display and adjustment module PLICSCOMVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321ServiceBasic adjustment 4DisplayDiagnostics▶Servic

Page 33

397 Set up with PACTware and other adjustment programsVEGABAR 54 • 4 … 20 mA/HART36726-EN-1303217 Set up with PACTware and other adjustment programs7

Page 34

41 About this documentVEGABAR 54 • 4 … 20 mA/HART36726-EN-1303211 About this document1.1 FunctionThis operating instructions manual provides all the

Page 35

407 Set up with PACTware and other adjustment programsVEGABAR 54 • 4 … 20 mA/HART36726-EN-13032112 43OPENTWISTUSBLOCKFig. 23: Connecting the PC via HA

Page 36 - 6.5 Menu schematic

417 Set up with PACTware and other adjustment programsVEGABAR 54 • 4 … 20 mA/HART36726-EN-1303217.3 Parameter adjustment with AMS™ and PDMFor VEGA se

Page 37

428MaintenanceandfaultrecticationVEGABAR 54 • 4 … 20 mA/HART36726-EN-1303218 Maintenanceandfaultrectication8.1 MaintainIf the instrument is

Page 38

438MaintenanceandfaultrecticationVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321Error code Cause Rectication4 … 20 mA signal not stableLeveluctuati

Page 39

448MaintenanceandfaultrecticationVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321Fperf=√((FT)2 + (FKl)2 (+ Fa)2)With:• Ftotal: Total deviation• Fperf

Page 40 - 1 VEGABAR 54

458MaintenanceandfaultrecticationVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321Total deviation analogue output signal absolute:Ftotal = 0.70 % x 8 ba

Page 41

468MaintenanceandfaultrecticationVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321data and displays the actual hardware and software version of the sens

Page 42 - 8.2 Rectifyfaults

479 DismountingVEGABAR 54 • 4 … 20 mA/HART36726-EN-1303219 Dismounting9.1 Dismounting stepsWarning:Before dismounting, be aware of dangerous process

Page 43 - DIN16086)

4810 SupplementVEGABAR 54 • 4 … 20 mA/HART36726-EN-13032110 Supplement10.1 Technical dataGeneral dataParameter, pressure Gauge pressure, absolute pre

Page 44

4910 SupplementVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321 Ʋ Transport cover PFAWeight approx.0.8 … 8 kg (1.764 … 17.64 lbs), depending on process tti

Page 45 - 8.5 Software update

52 For your safetyVEGABAR 54 • 4 … 20 mA/HART36726-EN-1303212 For your safety2.1 Authorised personnelAll operations described in this operating inst

Page 46 - 8.6 Instrument repair

5010 SupplementVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321Damping (63 % of the input variable) 0 … 999 s, adjustableAdditional output parameter - tempe

Page 47 - 9 Dismounting

5110 SupplementVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321Nominalrange Overload capacity, max. pressureOverload capacity, min. pres-sure-1 … +10 bar/-

Page 48 - 10 Supplement

5210 SupplementVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321Nominalrange Overload capacity, max. pressureOverload capacity, min. pres-sure-3 … +3 psig +

Page 49

5310 SupplementVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321 Ʋ Turn down 1 : 1 up to 5 : 1 < 0.1 %/10 K Ʋ Turn down up to 10 : 1 < 0.15 %/10 KOutsi

Page 50

5410 SupplementVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321 Ʋ PMC 316L PN 10 Ʋ Flange 316L PN 40Product temperature depending on the measuring cell seal

Page 51

5510 SupplementVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321Electromechanicaldata-versionIP66/IP68(1bar)Cable entry Ʋ Single chamber housing – 1

Page 52

5610 SupplementVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321Protection rating Ʋ unassembled IP 20 Ʋ mounted into the sensor without cover IP 40Material Ʋ

Page 53

5710 SupplementVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321Overvoltage category IIIProtection class IIFunctionalsafety(SIL)Functionalsafetyisalread

Page 54

5810 SupplementVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321Aluminium housing21ø 86 mm (3.39")~ 116 mm (4.57")116 mm (4.57")M20x1,5M20x1,5

Page 55

5910 SupplementVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321Stainless steel housing~ 69 mm(2.72")ø 79 mm(3.11")117 mm (4.61")M20x1,5/½ NPT

Page 56

62 For your safetyVEGABAR 54 • 4 … 20 mA/HART36726-EN-1303212.6 CE conformityThisdevicefulllsthelegalrequirementsoftheapplicableECguide-li

Page 57 - 10.2 Dimensions

6010 SupplementVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321External housing with version IP 681265 mm(2.68")68 mm(2.68")92 mm(3.62")42mm(

Page 58 - Aluminium housing

6110 SupplementVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321VEGABAR54,threadedttingGAGDGB22 mm(0.87")59 mm(2.32")40 mm(1.58")44 mm(1.7

Page 59

6210 SupplementVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321VEGABAR54,hygienictting1RI44,5 mm(1.75")G1 AGK67,5 mm(2.66")ø 52 mm (2.05"

Page 60

6310 SupplementVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321VEGABAR54,hygienictting2ø 62,5 mm(2.46")45 mm(1.77")REFig. 36: VEGABAR 54, hyg

Page 61 - SW 32 mm

6410 SupplementVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321VEGABAR54,angeconnection1DB, FZ, DA, F1d4kd2Dfb50 mm(1.97")DNmmPN DkbDB 15 40 95 16

Page 62 - VEGABAR54,hygienictting1

6510 SupplementVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321VEGABAR54,angeconnection2d2d4kDfbFA47,8 mm(1 7/8")2 43/64" 5/64"4xø 35/64

Page 63 - VEGABAR54,hygienictting2

6610 SupplementVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321VEGABAR54,connectionforpaperindustry145,5 mm(1 51/64")ø 26,3 mm (1 1/32")ø 36

Page 64

6710 SupplementVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321VEGABAR54,connectionforpaperindustry2VP VR ø 29,3 mm (1 5/32")30 mm(1 3/16")1

Page 65

6810 SupplementVEGABAR 54 • 4 … 20 mA/HART36726-EN-13032110.3 Industrial property rightsVEGA product lines are global protected by industrial propert

Page 66

69INDEXVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321INDEXAAccessories – Display and adjustment module 10 – External display and adjustment unit 10 – Ex

Page 67

73 Product descriptionVEGABAR 54 • 4 … 20 mA/HART36726-EN-1303213 Product description3.1 CongurationThe scope of delivery encompasses:• VEGABAR 54

Page 68 - 10.4 Trademark

70NotesVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321

Page 69

71NotesVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321

Page 70

Printing date:VEGA Grieshaber KGAm Hohenstein 11377761 SchiltachGermany36726-EN-130321All statements concerning scope of delivery, application, practi

Page 71

83 Product descriptionVEGABAR 54 • 4 … 20 mA/HART36726-EN-1303212113105436789111214Fig. 2: Layout of the type label (example)1 Instrument type2 Prod

Page 72 - Printing date:

93 Product descriptionVEGABAR 54 • 4 … 20 mA/HART36726-EN-130321The CERTEC® measuring cell is also equipped with a temperature sensor. The temperature