Page 1 - SOLITRAC 31

Operating InstructionsRadiation-based sensor for continuous level and interface measurementSOLITRAC 314 … 20 mA/HART - four-wireWith SIL qualicationD

Page 2 - Contents

103 Product descriptionSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119• Relative humidity 20 … 85 %3.5 Accessories and replacement partsThe d

Page 3

113 Product descriptionSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119responsibleauthority(inGermany,forexample,ocesforenviron-mental

Page 4 - 1 About this document

124 MountingSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-1311194 Mounting4.1 General instructionsThe source container is part of the measuring sy

Page 5 - 2 For your safety

134 MountingSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-1311194.2 Mounting instructionsNote:Along with the planning, our specialists will analys

Page 6 - 2.6 NAMUR recommendations

144 MountingSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119To measure the level in very high vessels, multiple instruments can be cascaded.Cas

Page 7 - 3 Product description

154 MountingSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119On vessels with temperature insulation, the sensor and the source container should

Page 8 - 3.3 System limitations

165 Connecting to power supplySOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-1311195 Connecting to power supply5.1 Preparing the connectionAlways

Page 9

175 Connecting to power supplySOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119If potential equalisation currents are expected, the connection o

Page 10 - 3 Product description

185 Connecting to power supplySOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-1311191Fig. 6: Connection steps 4 and 51 Locking of the terminal block

Page 11

195 Connecting to power supplySOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Information:The terminal blocks are pluggable and can be detached

Page 12 - 4 Mounting

2ContentsSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Contents1 About this document1.1 Function ...

Page 13 - 4.2 Mounting instructions

205 Connecting to power supplySOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Instruments with intrinsically safe current outputYoucannddet

Page 14

215 Connecting to power supplySOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-1311195.3 Connection - Level detectionNon-Ex instruments and instrumen

Page 15

225 Connecting to power supplySOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-1311191124/L/NPE562211122122 1920 18 17 14 1316 15 1221443Fig. 13: Elec

Page 16 - 5 Connecting to power supply

235 Connecting to power supplySOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119The instrument acts as Master and all other instruments operate a

Page 17 - 5 Connecting to power supply

245 Connecting to power supplySOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119112456 910112211122122 1920 18 17 14 1316 15 12112456 91011221112

Page 18

255 Connecting to power supplySOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Information:For example, a radial connection would be also possib

Page 19

266 Functional safety (SIL)SOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-1311196 Functional safety (SIL)6.1 ObjectiveIn case of dangerous outages,

Page 20

276 Functional safety (SIL)SOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119• 4 … 20 mA current output6.4 Safety concept of the parameterizatio

Page 21

286 Functional safety (SIL)SOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119All parameters changed by the operator are marked automatically so t

Page 22

297 Set up with the display and adjustment moduleSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-1311197 Set up with the display and adjustment modu

Page 23

3ContentsSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-1311199.2 Status messages ...

Page 24 - 43387-EN-131119

307 Set up with the display and adjustment moduleSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-1311197.2 Adjustment system12Fig. 17: Display and a

Page 25

317 Set up with the display and adjustment moduleSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Information:Inthisoperatinginstructionsman

Page 26 - 6 Functional safety (SIL)

327 Set up with the display and adjustment moduleSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Otherwise the instrument remains in the releas

Page 27 - 6 Functional safety (SIL)

337 Set up with the display and adjustment moduleSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Through this selection, the sensitivity of the

Page 28

347 Set up with the display and adjustment moduleSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Enter in the menu window "Max. process va

Page 29

357 Set up with the display and adjustment moduleSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Select "Linearization - New"toente

Page 30 - 7.2 Adjustment system

367 Set up with the display and adjustment moduleSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Because you have already set the background ra

Page 31

377 Set up with the display and adjustment moduleSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119If you know the level at a certain height, you

Page 32

387 Set up with the display and adjustment moduleSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119You can choose "no" reference value.

Page 33

397 Set up with the display and adjustment moduleSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Inasecondstep,allmodiedsafety-relevant

Page 34

41 About this documentSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-1311191 About this document1.1 FunctionThis operating instructions manual prov

Page 35

407 Set up with the display and adjustment moduleSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119points (Delta I). The value is an indication f

Page 36

417 Set up with the display and adjustment moduleSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Additional adjustmentsIn this menu item, the P

Page 37

427 Set up with the display and adjustment moduleSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Menu Menu item Default valueSetup Measurement

Page 38

437 Set up with the display and adjustment moduleSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119With this function• Load parameter adjustment

Page 39

447 Set up with the display and adjustment moduleSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119adjustment module. To do this you need PACTwar

Page 40

457 Set up with the display and adjustment moduleSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Setup: Settings, e.g. for measurement loop nam

Page 41

467 Set up with the display and adjustment moduleSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119When the output is active, the instrument has

Page 42

477 Set up with the display and adjustment moduleSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Additional adjustmentsWhen a reset is carried

Page 43

487 Set up with the display and adjustment moduleSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Menu Menu item Default valueSetup Measurement

Page 44

497 Set up with the display and adjustment moduleSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Information:Inthisoperatinginstructionsman

Page 45

52 For your safetySOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-1311192 For your safety2.1 Authorised personnelAll operations described in this o

Page 46

507 Set up with the display and adjustment moduleSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Otherwise the instrument remains in the releas

Page 47

517 Set up with the display and adjustment moduleSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Through this selection, the sensitivity of the

Page 48

527 Set up with the display and adjustment moduleSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119the adjustment of the sensor with full status

Page 49

537 Set up with the display and adjustment moduleSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Thechangebetweenthetwostatusesissucien

Page 50

547 Set up with the display and adjustment moduleSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119You can enter the adjustment point (ct/s) manu

Page 51

557 Set up with the display and adjustment moduleSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Dry run protection = the relay will deenergise

Page 52

567 Set up with the display and adjustment moduleSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119DisplayWith this parameter you can change the

Page 53

577 Set up with the display and adjustment moduleSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Pulse rate of the sensorCurrent outputSwitchin

Page 54

587 Set up with the display and adjustment moduleSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Basic settings: Resetting of the parameter adj

Page 55

597 Set up with the display and adjustment moduleSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119If the measured value is outputted via the 4 …

Page 56

62 For your safetySOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Only with class A instruments:The device is a class A instrument designed for

Page 57

608 Setup with PACTwareSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-1311198 Setup with PACTware8.1 Connect the PC213Fig. 18: Connection of the P

Page 58

618 Setup with PACTwareSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119• SOLITRAC 31• PCwithPACTwareandsuitableVEGADTM• VEGACONNECT4• HA

Page 59

628 Setup with PACTwareSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Fig. 20: Example of a DTM viewAll device DTMs are available as a free-of

Page 60 - 8 Setup with PACTware

639 Diagnostics and serviceSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-1311199 Diagnostics and service9.1 MaintenanceIf the device is used corre

Page 61 - 8 Setup with PACTware

649 Diagnostics and serviceSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Maintenance:Duetoexternalinuences,theinstrumentfunctionisl

Page 62

659 Diagnostics and serviceSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119CodeText mes-sageCause RecticationF036Faulty pro-gram memory – Erro

Page 63 - 9 Diagnostics and service

669 Diagnostics and serviceSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119CodeText mes-sageCause RecticationF120Filter time error – Faulty or

Page 64 - 9 Diagnostics and service

679 Diagnostics and serviceSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119CodeText mes-sageCause RecticationS017Accuracy outside the specica

Page 65

689 Diagnostics and serviceSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Error Cause Rectication4 … 20 mA signal missingElectrical connec-ti

Page 66

699 Diagnostics and serviceSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Sinceweoerthisserviceworldwide,thesupportisprovidedinEng

Page 67 - 9.3 Rectify faults

73 Product descriptionSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-1311193 Product description3.1 CongurationThenameplatecontainsthemostim

Page 68

709 Diagnostics and serviceSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119• Printandlloutoneformperinstrument• Clean the instrument an

Page 69 - 9.5 Software update

7110 DismountingSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-13111910 Dismounting10.1 Dismounting stepsWarning:Before dismounting, be aware of da

Page 70

7211 SupplementSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-13111911 Supplement11.1 Technical dataGeneral data316L corresponds to 1.4404 or 1.443

Page 71 - 10 Dismounting

7311 SupplementSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-13111912LFig. 22: Data of the input variable1 Min. level (red marking line)2 Max. le

Page 72 - 11 Supplement

7411 SupplementSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Output variable - Level measurementOutput signals 4 … 20 mA/HART - active; 4 … 2

Page 73

7511 SupplementSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119 Ʋ Max. 3 A AC, 1 A DCBreaking capacity Ʋ Min. 50 mW Ʋ Max. 750VAAC,40WDCIf

Page 74

7611 SupplementSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Process temperature (measured on the detector tube)-40 … +60 °C (-40 … +140 °F)W

Page 75

7711 SupplementSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Voltage supplyOperating voltage 20…72VDCor20…253VAC,50/60HzInterpola

Page 76

7811 SupplementSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Aluminium and stainless steel housing242,5 mm (9.55")54,5 mm(2.15")9 m

Page 77 - 11.2 Dimensions

7911 SupplementSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119SOLITRAC 3122 mm(0.87")36 mm(1.42")ø 76,2 mm(3")L242,5 mm (9.55&q

Page 78

83 Product descriptionSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119• Modicationstatuselectronicsfrom-07Theinstrumentisavailableind

Page 79

8011 SupplementSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119SOLITRAC 31 - Mounting example220 mm(8.66")70 mm(2.76")101,6 mm(4.00&q

Page 80

8111 SupplementSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-13111911.3 Industrial property rightsVEGA product lines are global protected by indus

Page 81 - 11.4 Trademark

82INDEXSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119INDEXAAccessories – External indicating unit 10Adjustment 33 – System 30Adjustment da

Page 82

83INDEXSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Summation Slave 43TTime 41, 57Type plate 7UUnit 51Units 33VVoltagesupply16, 77WW

Page 83

Printing date:VEGA Grieshaber KGAm Hohenstein 11377761 SchiltachGermany43387-EN-131119All statements concerning scope of delivery, application, practi

Page 84 - Printing date:

93 Product descriptionSOLITRAC 31 • 4 … 20 mA/HART - four-wire43387-EN-131119Due to the physical properties of the radioactive radiation, the pulse ra