Page 1 - Operating Instructions

Operating InstructionsVEGAVIB 66with contactless electronic switch

Page 2 - Contents

On the electronics module you will find the following indicatingand adjustment elements:l signal lamp for indication of the switching condition (green/

Page 3

4 Mounting4.1 GeneralIn general, VEGAVIB 66 can be mounted in any position. Theinstrument must be mounted in such a way that the vibratingelement is a

Page 4 - 1 Sequence

Warning:The housing must not be used to screw in the instrument!Applying tightening force on the housing can damage itsinternal mechanical parts.To sc

Page 5 - 2 For your safety

dd6123Fig. 4: Filling in the center, emptying laterally1 VEGAVIB 662 Emptying opening3 Filling openingThe vibrating element should protrude into the v

Page 6 - 2.8 Manufacturer declaration

Fig. 5: Inflowing materialTo minimise flow resistance caused by the tuning fork,VEGAVIB 66 should be mounted in such a way that thesurfaces of the fork

Page 7

This baffle must be manufactured by you.>125Fig. 7: Baffle protection against damagesVEGAVIB 66 - with contactless electronic switch 15Mounting29290-EN

Page 8 - 3 Product description

5 Connecting to power supply5.1 Preparing the connectionAlways observe the following safety instructions:l Connect only in the complete absence of lin

Page 9 - 3.3 Adjustment

1 Unscrew the housing cover2 Loosen compression nut of the cable entry3 Remove approx. 10 cm (4 in) of the cable mantle, stripapprox. 1 cm (0.4 in) in

Page 10 - 3.4 Storage and transport

14442 3Fig. 9: Material versions, single chamber housing1 Plastic (not with EExd)2 Aluminium3 Stainless steel (not with EExd)4 Filter element for pres

Page 11 - 4 Mounting

the electronics would be destroyed if connected directly to themains. It is not suitable for connection to low voltage PLCinputs.Domestic current is t

Page 12 - 4.2 Mounting information

Contents1 About this document1.1 Function ...41.2 Target group ...41.3 Symbolism used ...

Page 13 - 29290-EN-060508

6 Set up6.1 GeneralThe numbers in brackets refer to the following illustrations.On the electronics module you will find the following indicatingand adj

Page 14

With the potentiometer you can adapt the switching point to thesolid. It is already preset and must only be modified in specialcases.By default, the po

Page 15

Level Switching sta-tusControl lampMode min.Dry run protection21Switch closed GreenMode min.Dry run protection21Switch open redFailure of thesupply vo

Page 16 - 5 Connecting to power supply

7 Maintenance and fault rectification7.1 MaintenanceWhen used as directed in normal operation, VEGAVIB 66 iscompletely maintenance-free.7.2 Fault recti

Page 17

à Check if there is buildup on the vibrating element, and ifso, remove it.l Unfavourable installation locationà Mount the instrument at a location in

Page 18

21Fig. 13: Loosen the screws1 Electronics module2 Screws (2 pcs.)6 Remove the old oscillator7 Compare the new oscillator with the old one. The type la

Page 19

7.4 Instrument repairIf a repair is necessary, please proceed as follows:You can download a return form (23 KB) from our homepagewww.vega.com under: &

Page 20 - 6 Set up

8 Dismounting8.1 Dismounting procedureWarning:Before dismounting, be aware of dangerous process con-ditions such as e.g. pressure in the vessel, high

Page 21 - 6.3 Function chart

9 Supplement9.1 Technical dataGeneral dataMaterial 316L corresponds to 1.4404 or 1.4435Materials, wetted parts- Process fitting - Thread 316L- Process

Page 22

Process conditionsParameter Limit level of solidsProcess pressure -1 … 6 bar/-100 … 600 kPa (-14.5 … 87 psi)VEGAVIB 66 of 316L -20 … +80 °C (-4 … +176

Page 23 - 7.2 Fault rectification

8.2 Disposal ...279 Supplement9.1 Technical data...289.2 Dimensions ...319.3 I

Page 24

Protection class IApprovals1)ATEX II 1/2G, 2GEExd d IIC T6ATEX II 1/2 DIP66 T1)Deviating data in Ex applications: see separate safety instructions.Sup

Page 25

9.2 DimensionsVEGAVIB 66ø77mm (3 1/32")112mm (4 13/32")69mm (2 23/32")ø77mm (3 1/32")69mm (2 23/32")117mm (4 39/64")116m

Page 26 - 7.4 Instrument repair

150mm (5 29/32")L22mm(55/64")40mm(1 37/64")33mm(1 19/64")G1½Aø 43mm (1 11/16")ø 11mm (7/16")ø 43mm (1 11/16")160mm

Page 27 - 8 Dismounting

9.3 Industrial property rightsVEGA product lines are global protected by industrial property rights.Further information see http://www.vega.com.Only i

Page 28 - 9 Supplement

Supplement34 VEGAVIB 66 - with contactless electronic switch29290-EN-060508

Page 29

SupplementVEGAVIB 66 - with contactless electronic switch 3529290-EN-060508

Page 30 - ATEX II 1/2 DIP66 T

VEGA Grieshaber KGAm Hohenstein 11377761 SchiltachGermanyPhone +49 7836 50-0Fax +49 7836 50-201E-mail: [email protected] 9001All stateme

Page 31 - 9.2 Dimensions

1 About this document1.1 FunctionThis operating instructions manual has all the information youneed for quick setup and safe operation. Please read th

Page 32

2 For your safety2.1 Authorised personnelAll operations described in this operating instructions manualmust be carried out only by trained specialist

Page 33

2.6 SIL conformityVEGAVIB 66 fulfills the requirements of functional safetyaccording to IEC 61508/IEC 61511. You can find furtherinformation in the supp

Page 34

l Make sure that the cable gland is tight and strain-relieved.The outer diameter of the connection cable must beadapted to the cable gland. Tighten th

Page 35

3 Product description3.1 ConfigurationThe scope of delivery encompasses:l VEGAVIB 66 level sensorl documentation- this operating instructions manual- S

Page 36 - ISO 9001

Typical applications are overfill and dry run protection. Thanksto its simple and robust measuring system, VEGAVIB 66 isvirtually unaffected by the chem