Page 1 - Operating Instructions

Operating InstructionsVEGAVIB 55- two-wire

Page 2 - Contents

The packaging of standard instruments consists of environ-ment-friendly, recyclable cardboard. In addition, the sensor isprovided with a protective co

Page 3

4 Mounting4.1 General instructionsIn general, VEGAVIB 55 can be mounted in any position. Theinstrument must be mounted in such a way that the vibratin

Page 4 - 1 Sequence

Warning:The housing must not be used to screw the instrument in!Applying tightening force on the housing can damage itsrotational mechanical parts.To

Page 5 - 2 For your safety

To achieve a very precise switching point, you can installVEGAVIB 55 horizontally. However, if the switching point canhave a tolerance of a few centim

Page 6 - 2.6 Manufacturer declaration

12Fig. 5: Orientation of the tuning fork in case of flow1 Marking with screwed version2 Direction of flowIn case of horizontal mounting in adhesive prod

Page 7

5 Connecting to voltage supply5.1 Preparing the connectionGenerally note the following safety instructions:l Connect only in the complete absence of l

Page 8 - 3 Product description

10 Screw the housing cover back onThe electrical connection is finished.Fig. 7: Connection steps 5 and 65.3 Wiring plan, single chamber housing4123Fig.

Page 9 - 3.4 Storage and transport

For connection to a signal conditioning instrument. The sensoris powered via the connected signal conditioning instrument.For further information see

Page 10 - 29304-EN-070109

6 Setup6.1 IngeneralThe numbers in brackets refer to the following illustrations.On the electronics module you will find the following indicatingand ad

Page 11 - 4 Mounting

6.2 Adjustment elements4123Fig. 10: Electronics module - Two-wire output1 DIL switch for mode adjustment2 Ground terminal3 Screwed terminals4 Control

Page 12 - 4.2 Mounting instructions

Contents1 About this document1.1 Function ...41.2 Target group ...41.3 Symbolism used ...

Page 13

6.3 Function chartVEGAVIB 55 level switchThe following chart provides an overview of the switchingconditions depending on the adjusted mode and level.

Page 14

Mode on thesignal condi-tioning in-strumentLevel Signal cur-rent - Sen-sorSignal lamp- sensorSignallamp - sig-nal condi-tioning in-strumentMode AOverfi

Page 15 - 5.2 Connection procedure

7 Maintenance and fault rectification7.1 MaintenanceWhen used as directed in normal operation, VEGAVIB 55 iscompletely maintenance free.7.2 Remove inte

Page 16

à Check if there is buildup on the vibrating element, and ifso, remove it.l Unfavourable installation locationà Mount the instrument at a location in

Page 17

21Fig. 11: Loosen the screws1 Electronics module2 Screws (2 pcs.)6 Remove the old oscillator7 Compare the new oscillator with the old one. The type la

Page 18 - 6.1 Ingeneral

7.4 Instrument repairIf a repair is necessary, please proceed as follows:You can download a return form (23 KB) in the Internet fromour homepagewww.ve

Page 19 - 6.2 Adjustment elements

8 Dismounting8.1 Dismounting procedureWarning:Before dismounting, be aware of dangerous process con-ditions such as e.g. pressure in the vessel, high

Page 20 - 6.3 Function chart

9 Supplement9.1 Technical dataGeneral dataMaterial 316L corresponds to 1.4404 or 1.4435Materials, wetted parts- Process fitting - thread plastic PBT (P

Page 21

Process pressure -1 … 6 bar/-100 … 600 kPa (-14.5 … 87 psi)Process temperature -50 … +100 °C (-58 … +212 °F)Density >0.08 g/cm³ (0.003 lbs/in³)Elec

Page 22 - 7.2 Remove interferences

9.2 DimensionsVEGAVIB 5522mm(55/64")30,4mm(1 13/64")G1½A150mm (5 29/32")220,5mm (8 11/16")ø 43mm (1 11/16")Fig. 12: VEGAVIB 5

Page 23

9 Supplement9.1 Technical data...279.2 Dimensions ...299.3 Industrial property rights...3

Page 24

9.3 Industrial property rightsVEGA product lines are global protected by industrial property rights.Further information see http://www.vega.com.Only i

Page 25 - 7.4 Instrument repair

SupplementVEGAVIB 55 --two-wire 3129304-EN-070109

Page 26 - 8 Dismounting

VEGA Grieshaber KGAm Hohenstein 11377761 SchiltachGermanyPhone +49 7836 50-0Fax +49 7836 50-201E-mail: [email protected] 9001All stateme

Page 27 - 9 Supplement

1 About this document1.1 FunctionThis operating instructions manual has all the information youneed for quick setup and safe operation. Please read th

Page 28

2 For your safety2.1 Authorised personnelAll operations described in this operating instructions manualmust be carried out only by trained specialist

Page 29 - 9.2 Dimensions

2.6 Manufacturer declarationIn conformity with DIN EN 60079-14/2004, para. 5.2.3, pointc1, VEGAVIB 55 is suitable for use in zone 2.The operator must

Page 30 - 9.4 Trademark

2.7 Environmental instructionsProtection of the environment is one of our most importantduties. That is why we have introduced an environmentmanagemen

Page 31

3 Product description3.1 ConfigurationThe scope of delivery encompasses:l VEGAVIB 55 level sensorl Documentation- this operating instructions manual- S

Page 32 - ISO 9001

It functions even when exposed to strong external vibration orchanging products.Fault monitoringThe electronics of VEGAVIB 55 continuously monitors th