17
6 Supplement
VEGABAR 87 • 4 … 20 mA/HART
46690-EN-131125
6 Supplement
6.1 Technical data
Electromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 bar
Options of the cable entry
Ʋ Cable gland M20 x 1.5
Ʋ Cable diameter (options) 5 … 9 mm (0.20 … 0.35 in)
6 … 12 mm (0.24 … 0.47 in)
10 … 14 mm (0.39 … 0.55 in)
Ʋ Cable entry ½ NPT
Ʋ Blind plug M20 x 1.5; ½ NPT
Ʋ Closing cap M20 x 1.5; ½ NPT
Plug options
Ʋ Signal circuit PlugM12x1,accordingtoISO4400,HartingHAN,
7/8" FF
Ʋ Indication circuit M12 x 1 plug
Wire cross-section (spring-loaded terminals)
Ʋ Massivewire,cord 0.2 … 2.5 mm² (AWG 24 … 14)
Ʋ Stranded wire with end sleeve 0.2 … 1.5 mm² (AWG 24 … 16)
Voltage supply
Operating voltage U
B
Ʋ Non-Ex instrument 9.6 … 35 V DC
Ʋ Ex-d instrument 9.6 … 35 V DC
Ʋ Ex-ia instrument 9.6 … 30 V DC
Ʋ Ex-d-ia instrument 15 … 35 V DC
Ʋ Ex-d-ia instrument with ship approval 15 … 35 V DC
Interpolation protection Integrated
Permissibleresidualripple-Non-Ex,Ex-iainstrument
Ʋ for U
N
12 V DC (9.6 V< U
B
< 14 V) ≤0.7V
e
(16…400Hz)
Ʋ for U
N
24 V DC (18 V< U
B
< 35 V) ≤1.0V
e
(16…400Hz)
Permissible residual ripple - Ex-d-ia instrument
Ʋ for U
N
24 V DC (18 V< U
B
< 35 V) ≤1V
e
(16…400Hz)
Load resistor
Ʋ Calculation (U
B
- U
min
)/0.022 A
Ʋ Example - Non-Ex instrument with
U
B
= 24 V DC
(24V-9.6V)/0.022A=655Ω