32 VEGABAR 41 (Profibus PA)
Instrument modification
6 Instrument modification
6.1 Exchange of adjustment
modules
The modular construction of VEGABAR allows
retrofitting, interchange or removal of the
display module. Data previously saved (e.g.
adjustment values) are not stored in the ad-
justment module but in an EEPROM of the
electronics module and therefore
readjustment is not necessary. The
connection of the modules is made via a 4-
pole plug connection.
Exchange of the adjustment module
Removal of the adjustment module
Separate VEGABAR from the power
supply
Remove the screws on the upper side of
the housing and remove the cover or the
display module
Disconnect connection cables from the
terminals, and if applicable, pull out the
plug connection of the display module
Remove the two screws of the adjustment
module
Remove adjustment module and pull out
plug connection
Insertion of an adjustment module
Plug the plug connection of the new ad-
justment module into the plug-in socket of
the electronics module
Fasten the new adjustment module
Reconnect the connection cables, and if
applicable, also the cable from the
display module
Replace the cover or the display module
of VEGABAR
Reconnect VEGABAR to power supply
VEGABAR
Module
without
adjustment
Module for
menu-driven
adjustment
Display
module