Vega VEGABAR 64 Profibus PA User Manual Page 52

  • Download
  • Add to my manuals
  • Print
  • Page
    / 80
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 51
10 Supplement
10.1 Technical
data
General data
Parameter, pressure Gauge pressure, absolute pressure, vacuum
Measuring principle Ceramic-capacitive, dry measuring cell
Communication interface I²C bus
Materials and weights
Material 316L corresponds to 1.4404 or 1.4435
Materials, wetted parts
- Process tting 316L, PVDF, PVDF plated, Hastelloy C4 plated
- Diaphragm sapphire ceramic
®
(99.9 % oxide ceramic)
- Joining material diaphragm/Basic ele-
ment measuring cell
Glass solder
- Measuring cell seal FKM (VP2/A), FFKM (Kalrez 6375), EPDM (A+P
75.5/KW75F), FFKM (Chemraz 535), FFKM (FDA/
3A)
- Seal, process tting thread G1½ A Klingersil C-4400
Materials, non-wetted parts
- Electronics housing Plastic PBT (polyester), Alu die-casting powder-
coated, 316L
- External electronics housing plastic PBT (Polyester)
- Socket, wall mounting plate external
electronics housing
plastic PBT (Polyester)
- Seal between housing socket and wall
mounting plate
TPE (xed connected)
- Seal, housing cover NBR (stainless steel housing), silicone (Alu/plastic
housing)
- Inspection window in housing cover for
indicating and adjustment module
Polycarbonate (UL-746-C listed)
- Ground terminal 316Ti/316L
- Connection between IP 68 transmitter
and external electronics housing
PUR, FEP, PE
- Type plate support with IP 68 version on
cable
PE hard
Weight approx. 0.8 8 kg (1.764 17.64 lbs), depending on
process tting
Output variable
Output signal digital output signal, format according to IEEE-754
Sensor address 126 (default setting)
52 VEGABAR 64 Probus PA
10 Supplement
28252-EN-081209